Yes, it is the same as in the SPH series (except for SPH3000MM). Show Detail
When you set a password for Level 3 access control, you cannot change settings from the loader or clear the memory unless you enter the password for authenti... Show Detail
The execution order of the contacts and coils in a ladder circuit partly differs between MICREX-F and MICREX-SX. Therefore, if a MICREX-F program is convert... Show Detail
The amounts of data transmitted or received are not limited as R_WRITE instruction/R_READ instruction but by the capacity of the memory from/to which data ar... Show Detail
The set value of the timer must be a 32-bit (double-word) value. Specify DM (double-word), not WM (single-word). The memory to use may be DX or DL, as well a... Show Detail
The module is equipped with 2 channels of high-speed counter and signals of a different voltage can be counted for each channel. To set the signal level, s... Show Detail
When the initial value of REAL type is '5.0,' for example, processing it through Excel changes it to '5' of the INT type and that causes a data type mismatch... Show Detail
What is necessary for MODBUS_TCP communication between SPH and an external device?
The following are necessary. 1) Hardware Ethernet interface module (NP1L-ET1) or CPU module with built-in Ethernet (SPH2000/3000 series CPU types w... Show Detail
How can I use the pulse count function of the high-speed input module (Type_NP1X3206-A)?
We offer the sample program using the pulse count function for the high-speed input module. You can download the sample program and How-to Guide for it from... Show Detail
I want to equalize filter instructions in a redundant system.
Filter instructions are system FBs. System FBs that can be equalized are limited to_ The last value of the edge detection FB, present counter value of the co... Show Detail