What is the meaning of EN and ENO of functions in Expert (D300win)?
The EN and ENO terminals of functions mean the start operation terminal and the operation result terminal, respectively. ・When the variable connected to the... Show Detail
Once a compilation error occurs during patch POU, the project must be compiled and downloaded again. Therefore, you need to stop the CPU. Please consider the... Show Detail
Select 'PS32/PS74/PS117/PS245.' With the D300win, 'NP1PS-32/74/117' and 'NP1PS-32R/74R/117R' indicate the same model selection. This applies to all CPUs ... Show Detail
I use structure variables with the D300win. How each elements in structure assigned in memory?
Unfortunately, the member assignment in the structure is not disclosed. Show Detail
The current value of the timer can be changed. Note, however, that a circuit for changing the current value of the timer must be added. Show Detail
You can display the mismatch circuit in the program and differences using the 'Compare Projects' command of the Expert loader. For the operating procedure, ... Show Detail
The SX control utility of the D300win V2 supports the P-link area monitoring function from V2.2.6.0 and later. Check the version. Note that all versions of... Show Detail
When you do not check 'RETAIN' on the variable worksheet (default), the variable is treated as a non-retain memory. When you check 'RETAIN,' the variable i... Show Detail
With D300win V2, I cannot monitor some of the variables in the global variable worksheet.
They cannot be monitored if the number of rows in the variable worksheet exceeds 2520. Divide the variable worksheet so that the number of rows is 2500 or... Show Detail
Timers (or other FBs such as counters) each have an internal memory that is called an instance. Therefore, after copying a timer, you need to define a vari... Show Detail