Can I change a PLC program without a programming tool?
With a CPU module of the SPH Series that supports user ROM cards (CF or SD), a user ROM card can be used to download a program to the CPU module. Show Detail
To input the initial value, input '[value, value, ..., value].' In brackets, input values and use commas to separate values. Show Detail
The measurement accuracy does not include zero junction compensation accuracy. The zero junction compensation accuracy is ±1°C (at ambient temperature 0°C ... Show Detail
Yes, there are. When you install an expansion FB, sample programs are installed as a compressed project (extension *.Zpj) in a folder named 'SAMPLES' under... Show Detail
Can I install the D300winV2 and V3 on a single PC?
Unfortunately you can't. Show Detail
A 'client' is a device that collects data. Since the PLC is a device from which data is collected, there is no OPC client. Show Detail
The module counts feedback pulses even without Z-phase pulse signals. Note that when Z-phase pulse signals are not provided, origin return operation is dis... Show Detail
The counter is initially set to gate mode. Counting is disabled unless you provide a 'gate signal' externally by hardware or set 'gate disabled' by software.... Show Detail
The battery supplied with a CPU module is used to back up the following memories in the CPU module when a PLC system is turned off. Basically, connect the ba... Show Detail
What is the type of the configurator that is used with NP1L-PD1/PD2?
Use the following types of configurators: 'CONF-PDP' for NP1L-PD1 and 'NetTool for Profibus' for NP1L-PD2. Purchase a configurator from HMS Industrial Networ... Show Detail