What is the transfer data size range for the READ_WORD/WRITE_WORD FB?
The range in terms of description is up to 4096 words respectively. Note, however, that actual message transfer on the SX bus takes place after division into... Show Detail
The simulation function of the StandardV3 does not support the index register. Check the program operation using a hardware PLC. Show Detail
No, it is not necessary for normal operation. The main purposes of mounting a CF card or an SD card on a CPU module are as follows. - You can write a progr... Show Detail
The NP1F-HC2 constantly continues updating the pulse count value data for the SX bus I/F in a cycle of 200 ?s (fixed). The count data, however, will be refle... Show Detail
Yes, you can. Based on the rules of the IEC standard, you can omit 'X' in %MX, %IX, %QX and so on as long as they are BOOL type variables. Show Detail
This only stops the operating CPU and the operation is not switched to the standby CPU. Show Detail
Is broadcast communication via Ethernet possible?
It is possible as long as the protocol is UDP/IP. In the M_OPEN FB, specify 255.255.255.255 as the IP address to be set for the 'communication destination s... Show Detail
The version of the D300win is displayed as Version 4.0. Why?
This was probably caused by the following factors (1) The PC was not restarted after the D300win was installed. (2) A space is included in the name of the... Show Detail
No, it does not support multicast transmission (sending/receiving). It does support broadcast transmission (sending/receiving). Show Detail
Can I install the D300winV2 and V3 on a single PC?
Unfortunately you can't. Show Detail
211-220 of Total 398