If the start bit remains on, the positioning end signal is not generated. Show Detail
On the positioning module (Type_NP1F-MP2/MA2), the 'ERR' LED turns ON. What are the possible causes?
A possible cause is that a “Deviation amount over error” occurred. For details, refer to the user's manual FEH213 (NP1F-MA2) or FEH214 (NP1F-MP2) 'Section 8 ... Show Detail
Timers (or other FBs such as counters) each have an internal memory that is called an instance. Therefore, after copying a timer, you need to define a vari... Show Detail
The Standard loader has two types of timer devices created in projects: local timers (T0 to 8191) that are only valid in the POU and global timers (T8192 to... Show Detail
Yes, it is possible. Of the parameter setting items of initialization, changes made to specific parameter items (such as frame detection, code conversion and... Show Detail
Both the pulse output and control output are open collector outputs. They should be used within the following ranges (1) Pulse output_ 30 V DC, 40 mA or less... Show Detail
No, they won't. The programs will be executed from top to bottom for each task to which they are assigned, 'DEFAULT,' 'FIXED_CYCLE' and 'EVENT' respectively. Show Detail
Differentiation contacts and differentiation coils are instructions categorized as system FB. The instance number is a number indicating the area of the syst... Show Detail
Access the 'Programmable Controllers MICREX-SX Series' page in the Fuji Electric website, and click the 'Loader software' tab in 'PLC What's New.' You can d... Show Detail
I want MICREX-SX SPH models designed to resist sulfurized gas.
You can order sulfurized gas-resistant models by adding /Z4 at the end of product type code of the MICREX-SX SPH. Or, contact your Fuji Electric sales repres... Show Detail