No, they won't. The programs will be executed from top to bottom for each task to which they are assigned, 'DEFAULT,' 'FIXED_CYCLE' and 'EVENT' respectively. Show Detail
The multiplication of the high-speed counter module is automatically set as follows depending on the input pulse form_ ・ Forward pulse + Reverse pulse_ x1 ... Show Detail
Since the data equalization (data copying from the operating CPU to the standby CPU) is performed after the default task is processed, the larger the size of... Show Detail
The specified current value is constant regardless of the frequency because the input impedance for the pulse input I/F is fixed. Show Detail
When station number '0' is set on the servo, the station number set on the loader becomes effective. If, however, you want to use the servo for fail-soft st... Show Detail
You cannot use software filters when you use the pulse counter input function of the high-speed input module (Type_ NP1X3206-A). Show Detail
No, they are not synchronized. The configuration flag cannot be used for that application. Use the broadcast area for handshaking using the application to ... Show Detail
The SX does not allow the use of a single SPORT_NO (range_ 1 to 127) for multiple connections simultaneously. When you want to connect multiple ports, use a ... Show Detail
Project printing is optimized printing. The column width of a print is fixed and cannot be adjusted. Show Detail
On the positioning module (Type_NP1F-MP2/MA2), the 'ERR' LED turns ON. What are the possible causes?
A possible cause is that a “Deviation amount over error” occurred. For details, refer to the user's manual FEH213 (NP1F-MA2) or FEH214 (NP1F-MP2) 'Section 8 ... Show Detail
111-120 of Total 398