This only stops the operating CPU and the operation is not switched to the standby CPU. Show Detail
The temperature measurement value of the resistance temperature sensor (PT input) is unstable.
If this is caused by a fluctuation in the input temperature, moving average processing shown below may improve the condition. 1) Change the digital filter v... Show Detail
Use the 'Excitation timing output' signal for the Z-phase pulse when a stepping motor is used. Show Detail
Can I use a commercial LAN cable for the SX bus instead of the dedicated cable?
No, you can't. Although the connection of the sending/receiving wires of the SX bus cable is the same as that for a commercial LAN cable (cross), the dedica... Show Detail
The NP1F-HC2 constantly continues updating the pulse count value data for the SX bus I/F in a cycle of 200 ?s (fixed). The count data, however, will be refle... Show Detail
I use Expert (D300win). Can I check the download history to the CPU?
When downloading a project (including Patch POU), you can save the download history in your personal computer or the CPU module. [Setting procedure] ・In t... Show Detail
Note the following points (1) The rated output voltage is 12 to 24 V. Check the voltage of the device to be connected. (2) The Z-phase/timing input signal f... Show Detail
Yes, it is the same. Show Detail
NP4H-CB2 cannot be combined with a BLACK BOX converter for use. Use NP4H-CB2 in combination with a converter NW0H-CNV (for RS-232C) or NP4H-CVU (for USB). Show Detail
No, it cannot be used as it is. It requires resources to be added, the system configuration definitions to be changed, I/O groups to be reset and other ta... Show Detail
71-80 of Total 235