You can check it with the status indication LED on the front of the module. When a low battery voltage is detected, the CER LED on the front of the module ... Show Detail
The 'SND' and 'RCV' LEDs on the P-link module (Type_ NP1L-PL1) look dark. Is this a fault?
The LEDs of the P-link module (Type_ NP1L-PL1) are designed to blink quickly in accordance with the ON/OFF of a signal. Although they look dim to the human e... Show Detail
You can install only the USB driver afterwards. For V3.6.12.18 or later version of D300win, the USB driver can be installed at the time of installation of... Show Detail
The SPH system automatically inherits information such as the communication ports and reopening processing is not required. Show Detail
Selecting the DCE mode for the communication parameter_ DCE designation keeps DSR always on. Show Detail
Can I store multiple programs in the user ROM card (CF or SD) ?
No, it is not possible. Only one program can be stored. Show Detail
It is not possible with D300win V2. The sampling trace function is supported by D300win V3.1.1.0. or later. [Related document] Refer to Section '11-7 Sampl... Show Detail
No, it is not possible. Use an encoder of the line-driver or open-collector output type. When using a line-driver type, pay attention to the output capacity ... Show Detail
While 'DTR_ terminal ready' can be used with RS-232C, this control line is not present for RS-485. If no response is received while data are exchanged, re... Show Detail
Is it possible to use the optical converter NP1L-OL1 between processors as with the P-link?
The optical converter NP1L-OL1 is an optical converter of the SX bus. It cannot be used because the SX bus is not a link between processors. Show Detail