You can access the memory from a PC by setting the general-purpose communication module (Type_ NP1L-RS2) to 'Loader' mode. Various loader commands have been... Show Detail
It counts the number of transmissions of message processing M_RECEIVE and M_SEND performed on the SX bus. Show Detail
A 'client' is a device that collects data. Since the PLC is a device from which data is collected, there is no OPC client. Show Detail
No, it does not support the DPV1 function. It supports the DPV0 (I/O communication) function. Show Detail
Is it possible to use the optical converter NP1L-OL1 between processors as with the P-link?
The optical converter NP1L-OL1 is an optical converter of the SX bus. It cannot be used because the SX bus is not a link between processors. Show Detail
Can we use an FL-net module (Type_ NP1L-FL1/FL2/FL3) and standard LAN device with same network?
It is not possible. Each module comply to following FL-net standards. NP1L-FL1 : FL-netVer1 NP1L-FL2 : FL-netVer2 NP1L-FL3 : FL-netVer3(Class1) In FL-... Show Detail
No, they are not synchronized. The configuration flag cannot be used for that application. Use the broadcast area for handshaking using the application to ... Show Detail
How does the FL-net module (Type_ NP1L-FL1/FL2/FL3) clear the error history recorded in each memory?
Once an error history is generated, it is retained internally within the FL-net module and is cleared when the power is turned off and turned on again or whe... Show Detail
With a general-purpose communication module, is RS232C completely full duplex?
It is full duplex for both hardware and software (firmware) for anything other than communication by M_RECEIVE and M_SEND on the SX bus, which are FB interna... Show Detail
Does the general-purpose communication module support the BSC procedure?
No, it doesn't. Show Detail
11-20 of Total 53