In the alarm tracking display, alarm data is not tracked for the specified number of times.
<Cause> [Buffering Area Setting] → [Number of Data to Save] is small. <Solution> Increase the number set for [Number of Data to Save]. For ... Show Detail
When a character entry switch is pressed, the switch name on it disappears.
<Cause> The character entry key switch is set as [Draw Mode: REP]. <Solution> Set [Draw Mode: XOR]. When using characters from the graphic ... Show Detail
Negative values or decimal fractions cannot be entered with a keypad.
[Negative values cannot be entered] <Causes> Wrong operation of the keypad. The display type of entry target is set as "no sign". <Solutions... Show Detail
<V-Server> Are there any rstrictions on monitoring multiple devices by V-Server?
During logging or recipe transfer performed for one device, monitoring other devices is brought to a wait state. Due to that fact, V-Server may not be able ... Show Detail
How to designate entry targets in which data can be entered
Use the [Input Cursor Movement Control Device] setting. Example: When an entry target is placed on the screen, click [Screen Setting] -> [Screen Setting... Show Detail
How to change the design of a part placed on the screen
Two methods are available. Follow the steps below. [Method 1: Select a desired design from supplied parts] The following procedure uses the switch part as ... Show Detail
Set a value other than "0" for system memory $s77 (overlap exclusive function). Any switches other than those (including the overlap system button) on the o... Show Detail
I want to create a flow chart screen but it is too large to fit in single screen.
Images can be laid out four times the screen size in height or width. The whole are of a large image can be confirmed easily by scrolling the screen. As you... Show Detail
How to check the number of the screen currently displayed
The currently displayed screen number is stored in the following device memory areas. Device memory "n+2" in [Write Area] System device memory$s0 Writ... Show Detail
The POWER LED does not light up or flashes.
[The LED does not light up] <Causes> Power to the V/TS2060 series is not supplied properly. The LED is faulty (normal screen display). MONITOUCH is... Show Detail
301-310 of Total 315