  • Communication Error "Timeout"

    This error is displayed when the V series does not receive an answer from a connected device (PLC, temperature controller, etc.) within the predetermined tim... Show Detail

    • No:4547
    • Displayed Date:2025/12/01 13:47
  • Communication Error "Error code received"

    The "error code" in this message indicates errors occurring on the connected device side. Frequently occurring errors are: the PLC device memory address spec... Show Detail

    • No:4548
    • Displayed Date:2025/12/01 13:46
  • Screen Program Error "Error : XX (XX : XXX)"

    This error is displayed on the V series when an error is detected in the transferred screen data. <Solutions> Read the error code as shown below. F... Show Detail

    • No:4550
    • Displayed Date:2025/12/01 13:46
    • Updated DTM:2025/12/08 11:25
  • "The port cannot be opened."

    This error may be displayed on the configuration software V-SFT when data is transferred. When the PC port cannot be opened, this error occurs. [When "U... Show Detail

    • No:4555
    • Displayed Date:2025/12/01 13:47
    • Updated DTM:2025/12/15 10:32
  • A TCP connection cannot be established.

    This error occurs when a TCP connection cannot be established when connecting to a network device using TCP/IP. <Cause> The LAN cable is not connec... Show Detail

    • No:4569
    • Displayed Date:2025/12/01 13:46
    • Updated DTM:2025/12/08 11:49
  • Setup Error

    This error is displayed when there is no screen data or system program transferred to the V series. <Solution> Resolve the error according to the e... Show Detail

    • No:4551
    • Displayed Date:2025/12/01 13:47
  • I want to connect to MICREX-SX but "Communication Error: Error Code received " occurs.

    This is an address error. An invalid device memory is set in the screen program. The causes are listed below. Cause 1: X/Y device memory, P/PE link, or ... Show Detail

    • No:4566
    • Displayed Date:2025/12/01 13:46
    • Updated DTM:2025/12/08 11:33
  • "An error has occurred (123)"

    Characters which are not recognizable on your OS is used for the file name or the destination path. Or the file is saved in a deep directory. Rename the fil... Show Detail

    • No:4561
    • Displayed Date:2025/12/01 13:47
  • "Battery changeover required"

    This error is displayed in Local mode when a battery problem has occurred to the V series. (The battery is set in the V series at shipment.) <Cause>... Show Detail

    • No:4553
    • Displayed Date:2025/12/01 13:46
  • An error occurs in V-SFT when opening a screen program that connects to MICREX-SX

    This page describes the following errors. Screen programs for SX Programmer Expert (D300Win) projects Not exist a work sheet/group. It is DDE communicatio... Show Detail

    • No:4873
    • Displayed Date:2025/12/01 13:46