<Cause> The trend graph is not redrawn. <Solution> The graph data once displayed is not updated unless the redraw command is specified. To ... Show Detail
The graph of a trend part (Display Mode: Real Time Display) is not displayed.
<Causes> No data is stored in the device memory address for each graph number. The number of points to plot is not specified in the control device me... Show Detail
<TELLUS-HMI> I use storage or SRAM on the V series. How about in the TELLUS-HMI mode?
The data is saved in the PC. The data is stored in folders on your PC. Storage directory depends on the setting in [Optionn]→[Main 1]→[Generate folder at... Show Detail
MONITOUCH does not switch from the RUN screen to the Main Menu screen.
Press the [SYSTEM] switch, and when the switch menu is displayed press the [F1] (MODE) switch. [If the switch menu is not displayed when the [SYSTEM] sw... Show Detail
How to overlay one switch on another on the screen
As a rule, when placing switches, do not overlay one switch on another. When switches are overlaid, the switch placed on top is valid. The switch placed un... Show Detail
When Fuji Electric MICREX-SX is selected, this error is displayed if screen data uses input/output memory (X, Y), or P link/PE link/FL-net (CPU No. 8, 9) mem... Show Detail
<V-Server> I want to migrate the project generated on my PC to another one.
V-Server project consists of the folder and the files below: A project file (*.vpr) A folder which has the same name as the project file (A screen progr... Show Detail
<V-Server> Are there any rstrictions on monitoring multiple devices by V-Server?
During logging or recipe transfer performed for one device, monitoring other devices is brought to a wait state. Due to that fact, V-Server may not be able ... Show Detail
How to copy a TS/V8 screen program to V7 or earlier models
The TS/V8 screen program cannot be copied to V7 or earlier models. Copying of screens and parts such as switches also cannot be performed. Please recreated... Show Detail
Trend graphs cannot be displayed.
<Causes> No data is stored in the device memory address for each graph number. The number of points to display is not specified in the control device... Show Detail