Is it possible to indirectly specify the timer set value with the Standard Loader (Type_ NP4H-SWN)?
Yes, it is possible. Input a memory address (DLxx) instead of an immediate value as the operand of the timer instruction. Show Detail
Create one project file. There are separate tasks for the respective CPUs and the assignment of POUs to tasks determines the CPU to which the program is a... Show Detail
Does data monitoring of the I/O area require the module to be registered in the system definition?
Unless you register the module in the system definition and set the I/O group in the CPU parameters, data monitoring is disabled because no memory is reserve... Show Detail
A normal timer instruction specifies the effective timer range in the unit used on the POU. Since the timer numbers (T0 to T8191) are treated as a local devi... Show Detail
Yes, the SX series has a memory called 'system memory' to which flags indicating system operation statuses and fault statuses are assigned. Examples of the... Show Detail
The MICREX-SX is assumed to be installed inside a dustproof type switchboard in a general factory. The amount of dust mentioned above is assumed to cause no... Show Detail
The set value of the timer must be a 32-bit (double-word) value. Specify DM (double-word), not WM (single-word). The memory to use may be DX or DL, as well a... Show Detail
For the Standard loader V2, you cannot specify array data for the operand that specifies the first address. (An error is detected during the program check.) ... Show Detail
Yes, you can. On the 'Load from PLC' dialog, check 'Reflect Real Structure,' and then connect the PLC online. If this option is checked, the loader internall... Show Detail
When you enable optimization setting, compiling operation is changed to execute programs faster. Although different program codes are created, program execu... Show Detail