This error occurs when the system configuration set by the loader software differs from the actual configuration. For example, a defined module is not mount... Show Detail
Both Standard and Expert (D300win) are program loader software for the SX series. However, there is no compatibility between program data (called 'project')... Show Detail
Once a compilation error occurs during patch POU, the project must be compiled and downloaded again. Therefore, you need to stop the CPU. Please consider the... Show Detail
Where is the USB driver of USB/RS-422 converter for personal computer loader (Type_NP4H-CVU)?
The USB driver of USB/RS-422 converter for personal computer loader is stored in the 'UsbToSerial' folder in the 'Driver' folder in the folder where the pers... Show Detail
Check that the terminating plug is attached. Check also that the SX bus expansion cable is not broken. You need to attach an SX bus terminating plug at bot... Show Detail
What is the meaning of EN and ENO of functions in Expert (D300win)?
The EN and ENO terminals of functions mean the start operation terminal and the operation result terminal, respectively. ・When the variable connected to the... Show Detail
The MICREX-SX series T-link also has the fail-soft operation function, but not the general fail-soft function. In MICREX-SX, fail-soft operation can be ind... Show Detail
When you set a password for Level 3 access control, you cannot change settings from the loader or clear the memory unless you enter the password for authenti... Show Detail
To make the 'Use USB port' check box selectable, the USB driver for MICREX-SX must be installed on the PC in use. Install the USB driver (dedicated) conta... Show Detail
Does data monitoring of the I/O area require the module to be registered in the system definition?
Unless you register the module in the system definition and set the I/O group in the CPU parameters, data monitoring is disabled because no memory is reserve... Show Detail