There is a limit to the number of POUs that can be opened simultaneously_ 31 including 'Data 1,' 'Simulation' and 'AFB.' Show Detail
The Standard Loader does not support color printing. Show Detail
Yes, it is possible. Note, however, that the values are of the INT data type. Show Detail
1) By the mechanism of program conversion, unused FBs are also registered. However, FBs not used in the program are not downloaded to the CPU, therefor... Show Detail
Can a master control instruction be used in the MICREX-SX Series?
(1) For Expert (D300win) No master control instruction is provided. This is because the MICREX-SX Series is dedicated to programmable logic controlle... Show Detail
Does the SPH Series have SC instruction (step control instruction)?
The Standard Loader (V2.0.3.0 or later) supports SC instruction of the same specification as that of the MICREX-F Series. Show Detail
One likely cause is that any of the following characters is used in the variable worksheet (1) A double-byte space is used. Use a single-byte space or tab... Show Detail
The message appears when a zip project file (.zwt) contains 'DEFAULT.PLT' in which the page layout for project printing is set, and the page layout setting o... Show Detail
Can I change a PLC program without a programming tool?
With a CPU module of the SPH Series that supports user ROM cards (CF or SD), a user ROM card can be used to download a program to the CPU module. Show Detail
The error occurs because the address display mode is set to 'FLEX-PC,' but the address representation of the word device is not hexadecimal. For the addres... Show Detail
1-10 of Total 127