The lamp lights up even though the bit in the lamp device memory is not ON.
<Cause> The lamp device memory is used redundantly. <Solution> Check if the same address as the lamp device memory is used in the screen dat... Show Detail
Negative values or decimal fractions cannot be entered with a keypad.
[Negative values cannot be entered] <Causes> Wrong operation of the keypad. The display type of entry target is set as "no sign". <Solutions... Show Detail
Trend graphs cannot be displayed.
<Causes> No data is stored in the device memory address for each graph number. The number of points to display is not specified in the control device... Show Detail
The data displayed in a trend graph is different from the most recent data in the PLC.
<Cause> The trend graph is not redrawn. <Solution> The graph data once displayed is not updated unless the redraw command is specified. To ... Show Detail
The screen is not switched according to the command from the PLC (external).
The causes are listed below. <Causes> The screen number to display is not specified in read area "n + 2". The specified screen number is the same as... Show Detail
Ladder transfer cannot be performed properly.
The solution varies depending on the connection method between the PC and the V8/TS series. There are three connection methods: USB, Ethernet, serial (V-CP ... Show Detail
Characters are not displayed in character display parts as intended.
The action to take varies depending on the symptom. [No text is displayed or a part of text is not displayed] <Causes> Windows fonts are used but ... Show Detail
<Cause> When displaying a normal overlap or call-overlap part according to the status of the corresponding bit in read area "n + 1", this is recognize... Show Detail
Messages are not displayed in the alarm tracking display.
<Causes> [Start Bit] for sampling control device memory is checked, but the bit is not ON. The reset bit for sampling control device memory is ON. T... Show Detail
A screen in multiple languages is created; however, the displayed language does not change.
<Causes> A wrong language number is specified for the switch [Function: Language changeover]. (V8/TS series only) The screen is not refreshed after t... Show Detail