When a character entry switch is pressed, the switch name on it disappears.
<Cause> The character entry key switch is set as [Draw Mode: REP]. <Solution> Set [Draw Mode: XOR]. When using characters from the graphic ... Show Detail
Pressing the reset switch does not clear history data.
<Causes> The switch is not pressed twice. The switch function is not set to [Reset]. The switch is disabled according to the interlock setting. ... Show Detail
MONITOUCH does not recognize the storage dvice.
<Causes> The file system of the storage device is not supported. The CF card cover is open (V8 series only). The error status is set in $s497 (or $s... Show Detail
The PLC memory address for a part is garbled as "??" or is "blank".
<Causes> When the PLC model setting is changed, it is replaced with device "??". PLC2 - 8 (Temperature Control/PLC2Way with the V7 series) are set as... Show Detail
Click here. Show Detail
Previous numeric data or characters remain in a numerical data display or character display part.
<Causes> TS/V8/V7 series The number of parts with the [Transparent] or [Shadow] setting has exceeded the number available on one screen. V6 series... Show Detail
The time and date is not displayed correctly.
The solutions vary depending on the screen data settings. Check the following settings. Setting location: V-SFT editor [System Setting]→[Unit Setting]→[SR... Show Detail
Follow the steps below. Select [View] → [Display Environment] → [Display] tab window, and check [Display Device]. (Setting can be made by selecting the rig... Show Detail
How to designate entry targets in which data can be entered
Use the [Input Cursor Movement Device]. The [Input Cursor Movement Device] indicates the memory that controls whether to move the cursor to respective numer... Show Detail
How to set (correct) the calendar
The correction method differs depending on the calendar reading target (PLC or V/TS). For the reading target, check the following setting. Setting locati... Show Detail