How to copy a V10/V9 screen program to older models
The V10 screen program can be copied to V9. The V10/V9 screen program cannot be copied to the V8 or earlier models. [Copy from V10 to V9] Open each V10 and... Show Detail
This is possible by using a USB camera and the event recording function. [Setting example] Immediately before occurrence: 30 s Immediately after occurrenc... Show Detail
Can I make my macro commands more visible and easy to understand?
When coding a macro, use comment and tab. Comment: Texts after a semicolon(;) is recognized as a comment. It is useful to use it as a short notes of... Show Detail
How to replace a discontinued the MONITOUCH unit
The V9/V8/V7/V6/V4 series and GD-80 series can be replaced with the current models. Note that, however, the compatibility is not 100% and some restrictions ... Show Detail
I want to generate logging data in CSV at the determined time every day.
Use "storage output bit" in logging server and "scheduler function" together. E.g.)Logging data is output in csv file at 23:00pm everyday: 1) Storage out... Show Detail
How to sound a buzzer according to a command from the PLC (external)
Follow the procedure below. * For V8-compatible screen programs, use [Read Area]. Click [System Setting]→[Unit Setting]→[Buzzer] on the V-SFT editor. ... Show Detail
How to display overlap parts from the PLC (external)
There are four overlap part types. Normal overlap Call-overlap Multi overlap Global overlap In the case of external commands, the display method diffe... Show Detail
How to set (correct) the calendar
The correction method differs depending on the calendar reading target (PLC or V10/V9 series). For the reading target, check the following setting. Setting... Show Detail
I want to have scrolling alarm messages on my screen.
Alarm server setting has scrolling message feature. Byselecting "Flowing message" as an action to take when alarm occurs, alarm message areaappears on the... Show Detail
How to check the operation of screens without connecting to a PLC
Use the simulator. The simulator allows you to verify screen operations without a PLC. The simulator runs on a PC and simulates bit device ON/OFF action an... Show Detail