You can change it to zero-suppress display from [Display Environment] menu. Follow the step below. Go to [View] > [Display Environment]. Check ... Show Detail
A screen in multiple languages is created; however, the displayed language cannot be switched.
<Causes> A wrong language number is specified for the switch [Function: Language changeover]. The screen is not refreshed after the execution of macr... Show Detail
<Cause> The trend graph is not redrawn. <Solution> The graph data once displayed is not updated unless the redraw command is specified. To ... Show Detail
I want to show a multi-overlap using PLC command but the overlap does not appear.
Check the following points: Multi-overlap (icon) is not place on the screen. Multi-overlap setting (icon) is not correct. Macro commands are not corr... Show Detail
Messages are not displayed in the alarm tracking display.
<Causes> The bit corresponding to the message is not ON. The display mode for displaying messages is not checked in the [Alarm Device] settings of th... Show Detail
The graph of a trend part (Display Mode: Real Time Display) is not displayed.
<Causes> No data is stored in the device memory address for each graph number. The number of points to plot is not specified in the control device me... Show Detail
The lamp lights up even though the bit in the lamp device memory is not ON (OFF).
<Cause> The lamp device memory is used redundantly. <Solution> Check if the same address as the lamp device memory is used in the screen data ... Show Detail
Pressing the reset switch does not clear history data.
<Causes> The switch is not pressed twice. The switch is disabled according to the interlock setting. <Solutions> Press the "Reset" switch... Show Detail