I do not want to show a status bar on the bottom right corner of V series screen.
You can hide the status bar in the following way. Method 1: Click [x] on the status bar to temporarily hide it. Method 2: Use "Status Bar Prohibited" setti... Show Detail
I have a communication problem between the V10/V9 and Mitsubishi Q series CPU via Ethernet unit.
Please check the settings below: Screen program settings: [System Setting]→[Hardware Setting] Select [QnH (Q) series (Ethernet)] at [Device Select]. ... Show Detail
<Cause> The setting for [System Setting] -> [Alarm Server] -> [Data Output Setting] -> [Number of Data to Save] is small. <Solution>... Show Detail
Pressing the touch switch activates nothing or activates a position that deviates from the switch.
Try performing touch switch testing and adjustment. Display the touch switch test screen. - V10/V9 Standard, V9 Lite model Local mode [I/O Check] men... Show Detail
<Cause> When a control device memory bit is used to display a normal overlap or call-overlap part, only the leading edge (OFF -> ON) is recognized.... Show Detail
Ladder transfer cannot be performed properly.
The solution varies depending on the connection method between the PC and the V10/V9 series. There are three connection methods: USB, Ethernet, and serial (... Show Detail
<Cause> The trend graph is not redrawn. <Solution> The graph data once displayed is not updated unless the redraw command is specified. To ... Show Detail
The V series does not switch from the RUN screen to Local mode.
Click here for the method for switching to Local mode. [If the switch menu is not displayed when the [SYSTEM] switch is pressed] <Cause> Advanced ... Show Detail
I want to show a multi-overlap using a button but the overlap does not appear.
Check the following points: <Causes> Multi-overlap (icon) is not place on the screen. Multi-overlap setting (icon) is not correct. Macro command... Show Detail
I have a communication problem between the V10/V9 and Mitsubishi QnU series CPU built-in Ethernet.
Please check the settings below: Screen program settings: [System Setting]→[Hardware Setting] Select [Model: QnU series (Built-in Ethernet)] at [Devi... Show Detail