The Standard Loader does not support color printing. Show Detail
Yes, it is possible. Show Detail
The text color of I/O addresses (X, Y) is red. You cannot change it. Show Detail
You can remove these warnings by deleting function blocks (FBs) that are not used in the program. Do either of the following methods: Method 1 1) After... Show Detail
How can I use the present value of the timer (TON) with the Standard Loader (Type_ NP4H-SWN)?
You can set the present timer value by specifying the operand with identifier T. Example_ |--| |--[ MOVE T0 ? DM10 ]--| Show Detail
For device display in StandardV3, a maximum of 2048 rows can be displayed on one window. To display WM2048 and the following addresses, click the [Next page]... Show Detail
How can I display the list of device use status on Standard loaderV3
1) Double-click the 'Device' icon in the project view to open the device window. 2) Click the [Device Type] selection button (▼) and select a device the u... Show Detail
The set value of the timer must be a 32-bit (double-word) value. Specify DM (double-word), not WM (single-word). The memory to use may be DX or DL, as well a... Show Detail
Is it possible to indirectly specify the timer set value with the Standard Loader (Type_ NP4H-SWN)?
Yes, it is possible. Input a memory address (DLxx) instead of an immediate value as the operand of the timer instruction. Show Detail